The Util Box

Structural Load

Free online structural load. Dead/live load estimation. 100% client-side — your data stays private.

Load Combinations
1.4D2.10 kN/m²
1.2D + 1.6L4.84 kN/m²
1.2D + 1.0W1.80 kN/m²
1.2D + 1.0L + 1.0W3.70 kN/m²
1.2D + 1.0L + 1.0S3.70 kN/m²
0.9D + 1.0W1.35 kN/m²
Governing: 1.2D + 1.6L = 4.84 kN/m²
Total Load per Area
4.84 kN/m²
Total Load on Structure
484.00 kN

Embed this tool

Copy and paste the code below into your website to embed this tool for free. An attribution link to The Util Box is required.

<iframe src="https://www.theutilbox.org/embed/structural-load-calculator" width="600" height="500" frameborder="0" style="border: none; max-width: 100%;" title="Free Structural Load tool from The Util Box"></iframe>
<!-- Free tool by The Util Box — https://www.theutilbox.org/tools/structural-load-calculator -->
<a href="https://www.theutilbox.org/tools/structural-load-calculator">Structural Load by The Util Box</a>

Frequently Asked Questions about Structural Load

Structural Load Calculator — Factored Load Combinations

This structural load calculator applies the standard factored load combinations to a set of dead, live, snow and wind loads, and tells you which combination governs. You enter the loads as pressures and the tool works out the factored value of each combination, highlights the largest, and multiplies it by your floor area to get the total load on the structure.

Three presets set typical values for residential, commercial and roof construction, and the units toggle between metric (kN/m²) and imperial (psf).

The Six Load Combinations

Combination Formula
1.4D Dead load alone, factored by 1.4
1.2D + 1.6L Dead and live load together
1.2D + 1.0W Dead load with wind
1.2D + 1.0L + 1.0W Dead, live and wind together
1.2D + 1.0L + 1.0S Dead, live and snow together
0.9D + 1.0W Dead load reduced by 10% with wind

The pattern is the point of the exercise: each combination pairs the loads that can act at the same time and applies a factor to each. A combination that includes live load gets a larger factor because people move about while the building is in use; a combination with snow or wind uses 1.0 because those are transient and do not coincide with full occupancy.

Honest Limits

  • This is a representative set of combinations, not a code's full list. Eurocode uses a different set of factors, and ASCE 7 includes combinations with 1.6D and 0.6D that are not here. Use the set your engineer is designing to.
  • The presets always fill in metric values. If you have switched to imperial and then click a building type, the metric figure is written into a box labelled psf. Convert your own numbers rather than relying on the presets in imperial mode.
  • The building-type figures are rough typical values, not code-mandated minimums, and they vary enormously with the actual construction.
  • No seismic loading, and no wind uplift or drag on roofs — which often governs a light roof structure.
  • One lumped area. You cannot model a roof with a heavy plant area and a light balcony, and there is no load path, no member sizing and no deflection check.